[Simultaneous Determination of 8 Illegal Synthetic Drugs in Antihypertensive Dietary Supplements by High Performance Liquid Chromatography-Mass Spectrometry].

Lu Yaling,Chen Jitao,Chen Bo,Yao Shouzhuo
DOI: https://doi.org/10.3321/j.issn:1000-8713.2009.01.008
2009-01-01
Abstract:A method of high performance liquid chromatography-mass spectrometry (HPLC-MS) for the simultaneous determination of 8 illegal synthetic drugs in antihypertensive dietary supplements was developed. The chromatography was performed using a Spherigel C18 column, with the mobile phase of 0.005 mol/L ammonium formate buffer (pH 3.0)-acetonitrile-methanol and cialis as internal standard. In ESI mode, the lowest concentration limit of detection (LOD) was 2.5 microg/L and the lowest concentration limit of quantification (LOQ) was 8.3 microg/L, while in ESI- mode, the lowest concentration limit of detection (LOD) was 50 microg/L. The average recoveries were between 63.3% - 107.4%. The clonidine, dihydrochlorothiazide, triamterene, metoprolol, phentolamine, chlorthalidone, furosemide and valsartan in the samples were separated well under the optimized conditions. The method was well validated by systematical searching for satisfactory conditions using the experimental designs including precision, repeatability and spiked recovery.
What problem does this paper attempt to address?