[Determination of 8 Trace Elements in Mantle Muscle and Cuttlebone of Sepiella Maindroni by ICP-MS Using Microwave Digestion for Sample Preparation].

Wu Chang-wen,Chi Chang Feng,He Guang-yuan,Xu Mei-ying
DOI: https://doi.org/10.3964/j.issn.1000-0593(2009)12-3395-04
2009-01-01
Abstract:An inductively coupled plasma mass spectrometry (ICP-MS) for determination of the contents of 8 trace elements in mantle muscle and cuttlebone of Sepiella maindroni after microwave digestion of the sample has been developed. Satisfactory linearity of working curves for the 8 elements was obtained, giving all their correlation coefficients over 0.997 3. The precision of measurement ranges from 2.4% to 8.7% in terms of relative standard deviation. The recoveries and the limits of detection are in the range of 96.5%-106.3% and 0.002-0.032 microg x L(-1), respectively. It was indicated that the proposed method had the advantages of simplicity, speediness and sensitivity. The results showed that the mantle muscle and cuttlebone of Sepiella maindroni contained rich trace elements Zn and Cu, but the contents of Cd and As are higher than the limits of Chinese Pharmacopoeia, Green Trade Standard for Importing and Exporting Medicinal Plant and Preparation and U.S. Food and Drug Standard. Furthermore, our study provides new scientific foundation for the quality control, culture, general application, resource utilization and exporting of Sepiella maindroni.
What problem does this paper attempt to address?