Determination of Metallic Element in Soybean Coat by Fermentation-Microwave Digestion-Microwave after Semi-Ashing Plasma Torch Atomic Emission Spectrometry
LI Xiu-ping,ZHAO Rong-xiang,LI Li-hua,ZHANG Jin-sheng
2011-01-01
Abstract:Soybean coat samples were digested by H2O2-HNO3 solution after semi-ashing in a closed microwave system and the determination of iron,nickel,magnesium,calcium zinc and copper in soybean coat has been performed by MPT-AES.Experimenta1 conditions were optimized and established.The effects of acid concentration and coexisting ions(K,Na,Fe,Ni,Al,Zn,M g,Ca)on determination of iron,nickel,magnesium,calcium zinc and copper were investigated.The results showed that the detection limits of iron,nickel,magnesium,calcium,zinc and copper were 22.94,7.55,0.36,0.92,16.27 and 2.1 ng·mL-1,respectively.The RSD was no more than 3.2%,it showed the adopted method had good precision.The linear ranges of iron,nickel,magnesium,calcium,zinc and copper were 0-12,0-12,0-35,0-32,0-7 and 0-12 μg·mL-1,respectively.The recoveries were 96.8%-101.3%,98.4%-103.7%,95.9%-99.6%,96.3%-103.5%,99.8%-103.5% and 97.6%-105.3%,respectively.Compared with conventional test methods,MPT combined with half ash and microwave digestion samples was efficient with high accuracy and repeatability and applicable to sample analysis.