Xuejun TAN,Li TANG,Qi ZHOU
DOI: https://doi.org/10.3321/j.issn:0253-374X.2008.08.016
2008-01-01
Abstract:Performance of low temperature Sequencing Batch Reactor £¨SBR£© system was studied via the investigation of pollutants removal, parameters control, biological activity and sludge characteristics. The results show that Chemical Oxygen Demand £¨COD£© removal in low temperature SBR system is divided into two stages, and nitrification reaction occurs on in the second stage. 2,3,5-triphenyl-tetra- zolium Chloride TTC and 2-£¨p-iodophenyl£©-3-£¨p-nitrophenyl£©-5-phenyl-tetrazolium Chloride £¨INT£©- Electron Transport System £¨ETS£© activity and Oxygen Uptake Rate £¨OUR£© of activate sludge changed periodically in the low temperature SBR system. The variation of TTC and INT-ETS activity can provide suitable information about the process of the whole SBR system, and OUR can reflect the biochemical reaction of the aerobic stage£o pH values provide a good indication of the ongoing biological reactions for the whole process, Dissolved Oxygen £¨DO£© only fits for aerobic process and Oxidation Reduction Potential £¨ORP£© is unsuitable for low temperature SBR process control. Mixed Liquid Volatile Suspended Solid £¨MLVSS£©/Mired Liquid Suspended Solid £¨MISS£© of low temperature SBR system rises with the increase of operation cycle, and when system remains stable, MLVSS/MLSS of low temperature system is higher than that of normal temperature system.