Rapid Quantification of Tiopronin in Human Plasma by High-Performance Liquid Chromatography-Mass Spectrometry

LIU Na,ZHANG Bei-bei,ZHANG Zun-jian,TIAN Yuan,XU Feng-guo,CHEN Yun
DOI: https://doi.org/10.3321/j.issn:1000-5048.2008.01.012
2008-01-01
Abstract:Aim:To develop a rapid high-performance liquid chromatography-mass spectrometry (HPLC-MS) method for the quantification of tiopronin in human plasma.Methods:Cysteine was chosen as antioxidant and firstly added into the whole blood firstly.After adding mycophenolic acid as internal standard (IS) and 1 mol/L HCl into the plasma,the samples were extracted with acetic ether and then determined by HPLC-MS.The chromatographic separation was performed on a Shim-pack VP-ODS C18 column (250 mm×2.0 mm,5 μm) using methanol-0.1% acetic acid (70∶30) as mobile phase with a flow rate of 0.2 mL/min.Results:The assay exhibited a linear range of tiopronin between 30~4 000 ng/mL.The precisions for intra- and inter-batch were all within 8.5%.The extraction recoveries were more than 70%.The total HPLC-MS analysis time was within 7.5 min per a run.The fully validated method was successfully applied to quantify tiopronin in human plasma for a bioavailability study.Conclusion:The assay proved to be accurate,sensitive,selective and convenient.The fully validated method can be applied to study the pharmacokinetics and bioavailability of tiopronin and tiopronin formulations in human.
What problem does this paper attempt to address?