Performance of an Intermittently Loaded Bio-trickling Filter for Treating Organic Waste Vapors from Printing and Coating Facilities

HUA Su-lan,WANG Li-ping,ZHOU Min,ZHU Yu-li,WU Xiao
DOI: https://doi.org/10.3321/j.issn:1000-1964.2008.01.016
2008-01-01
Journal of China University of Mining and Technology
Abstract:The performance and degradation mechanism of a pilot-scale bio-trickling filter(Φ 300×2 000 mm) for treating organic waste vapors produced from printing and coating facilities was investigated under two different intermittent loading conditions.The bio-filter was started by adding P.putida consortium using a "gas-liquid phase joint inoculation" method and an "inducer-target graded acclimation" method.The results show that the bio-filter is effective for treating organic waste vapors during the daytime operating period.When the inlet gas concentration is in the range of 550-750 mg/m3 the empty bed residence time(EBRT) is 30.3 s and the elimination efficiency of TVOC,toluene and ethyl acetate are greater than 85%,95% and 80%,respectively.Two days of contaminant loading after the weekend shutdown period were required to regain the full elimination capacity.A closed-system batch experiment on aerobic toluene degradation showed that there are several intermediates,such as catechol and benzyl alcohol,that accumulate during bio-degradation.The good performance is demonstrably due to the oxidation of intermediates linked to biomass synthesis during shutdown periods.