CFD ANALYSIS AND RESULT VALIDATION OF A CERTAIN CENTRIFUGAL COMPRESSOR IMPELLER

Xiang LI,Chun-Wei GU
DOI: https://doi.org/10.3321/j.issn:0253-231X.2008.08.008
2008-01-01
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Abstract:In this paper, the three dimensional flow in a certain centrifugal impeller was investigated on the basis of a detailed analysis of the results of numerical simulation. In order to gain confidence in this process, validation was performed based on the comparison of numerical result and experimental data using commercial software NUMECA. Results show that in general the numerical simulation matches well with experiment, but CFD calculation cannot predict the near surge condition and made a relatively big difference in large flow rate condition, also, it tends to exaggerate the low velocity region. The influence of tip leakage flow is studied in this paper as well, due to the small number of blades, secondary flow is very large in this impeller, the introduction of leakage flow can reduce the low velocity region and thus increase efficiency.
What problem does this paper attempt to address?