Removal of Toluene by Gliding Arc Discharge Plasma

DU Chang-ming,LI Jun-ling,YAN Jian-hua
DOI: https://doi.org/10.13336/j.1003-6520.hve.2008.03.002
2008-01-01
Abstract:To remove volatile organic compounds(VOCs) by gliding arc discharge plasma technology,the effect of plasma reactor configuration parameters(electrode gap distance,electrode material,electrode thickness,oxygen content,water content,gas temperature and inlet VOCs concentration) on the toluene removal efficiencies was experimentally researched.The toluene removal efficiency 90% was obtained when specific energy input,electrode gap distance,electrode thickness,gas flow rate,inlet concentration of toluene were 0.26 kWh/m3,3mm,4mm,0.8 m3/h,7 850 mg/L respectively,and the max energy efficiency was about 26.92 g/kWh.The effect of the electrode material on toluene removal was negligible.The toluene removal efficiencies increase as the oxygen content,water content and gas temperature increase;but decrease with increasing inlet VOCs concentration.
What problem does this paper attempt to address?