"Mechanism Of Flexural Resonance Frequency Shift Of A Piezoelectric Microcantilever Sensor During Humidity Detection" [Appl. Phys. Lett. 92, 183505 (2008)]

Fei Wang,Jiaying Chen,Xuezeng Zhao
DOI: https://doi.org/10.1063/1.2977594
IF: 4
2008-01-01
Applied Physics Letters
Abstract:Some significant findings related to the mechanism of flexural resonance frequency shift of a piezoelectric microcantilever (PEM) sensor during humidity detection. It was observed during the study that the mass change due to variation of humidity can make an impact on Young's modulus of the PEM sensor. The study also revealed that the viscous damping effect of air on the vibration of a PEM may also cause the frequency shift of a PEM sensor during the humidity change. The resonance frequencies can be affected by the fluid density and viscosity in which it immersed when structural and radiation damping are very low compare to dissipative viscous effects in the fluid. The study also found that the Reynolds number for vibration of the PEM immersed in air increases with the decrease of humidity. The study concluded that viscous damping effect can alter the resonance frequency shifts.