Content determination of epigoitrin in Radix Isatidis and its preparation by RP-HPLC

Yi-qiang AN,Xiao-bin JIA,Hai-jian YUAN,E SUN,Zhen-zhen XU
DOI: https://doi.org/10.3321/j.issn:1001-5302.2008.18.015
2008-01-01
Abstract:Objective: To establish an HPLC method for the content determination of epigoitrin in Radix Isatidis and its preparation, and to provide valuable data for quality control of Radix Isatidis and its preparation. Method: The samples were separated on a ZORBAX SB - C18 (4.6 mm x 150 mm, 5 μm) column with the mobile phase of acetonitrile-water-phosphoric acid-triethylamine (8.50:90.72:0.73:0.05) in the flow rate of 0.7 mL·min -1. The detection wavelength was set at 245 nm. Column temperature was 30°C. Result: The linear range of epigoitrin was 0.020 4-0. 3060 μg (r = 0.9998), and the average recovery was 98.99% with the RSD was 1.31% (n = 9). Conclusion.. The method for quantitation of epigoitrin in Radix Isatidis and its preparation was accurate and reliable, which can be used to evaluate the quality of Radix Isatidis and its preparation.