Determination of Medium Concentration Urea in Solution by P-Dimethylaminobenzaldehyde Colorimetry

刘志刚,赵庆良,孙丽欣,邱微
DOI: https://doi.org/10.3321/j.issn:0367-6234.2008.08.008
2008-01-01
Abstract:In order to provide an easy and rapid method for measuring urea concentration in solution,the p-dimethylaminobenzaldehyde(PDAB) colorimetry was studied.The analysis conditions,characteristics,the analysis range of PDAB colorimetry for urea,as well as the influence of sodium chloride(NaCl) and ammonium nitrogen concentration on the determination method were all tested.The results showed that the optimum wavelength was 422 nm,the reaction time was 10 min,and the reaction regent ratio of PDAB(w/g),oil of vitriol(V/mL) and absolute alcohol(V/mL) was 4:4:96.Under these determination conditions,the analysis range of urea concentration was 8.8 to 107 mg/L.When the concentration of ammonium nitrogen was less than 300 mg/L and that of NaCl was between 400 and 8000 mg/L,the good results were also obtained.Therefore,this method is suitable to determine the medium urea concentration in solution,which contains higher concentration of ammonium nitrogen or NaCl,and it is quick,stable and easy to operate.