Preliminary Study on Application of Pd Composite Membrane in Helium Purification System of High-Temperature Gas-Cooled Reactor

CAO Jian-hua,YANG Xiao-yong,WANG Jie,YU Su-yuan
2008-01-01
Abstract:Helium purification system(HPS) is the main part of the helium auxiliary system of high-temperature gas-cooled reactors(HTGR),also in fusion reactors.Some exploratory work was carried out on the application of Pd composite membrane in the separation of He and H2.A typical single stripper permeator with recycle(SSP) system was designed,based on the design parameters of a small scale He purification test system CIGNE in CADARACHE,CEA,France,and finite element analysis method was used to solve the model.The total length of membrane module is fixed to 0.5 m.The results show that the concentration of H2 is found to reduce from 1 000 μL/L in feed gas to 5 μL/L in the product He(the upper limitation of HPS in HTGR).And the molar ratio of product He to feed gas is 96.18% with the optimized ratio of sweep gas to retentive gas 0.397 0.It's an exponential distribution of H2 concentration along the membrane module.The results were also compared with the other two popular designs,two stripper in series permeator(TSSP) and continuous membrane column(CMC).