Abstract:In the laser rangefinder system, the temperature control system is a critical issue which can avoid the thermal fluctuating to affect the modulation characteristic of the laser diode and the receptivity of the avalanche photodiode. A proper structure of temperature control system was designed to reduce the environment impact on temperature controlling. The main error sources of using Platinum resistor in temperature measurement were analyzed in detail, and a new set of circuit based on pulse current drive was proposed. The self -heat effect of the pulse current drive was studied and the relationship between pulse width and heat quantity accumulation was given. The thermometric error from self -heating effect was decreased greatly by controlling the pulse width properly. The platinum resistor nonlinear was compensated with higher order orthogonal polynomial fitting method. The high precision compensation was proven by comparing data of the temperature measuring module and of the absolute standard Platinum resistance thermometer. The absolute value of maximum error is 0.000 6 ℃ at different temperature spots from 0 ℃ to 15 ℃. The temperature stability is about ±0.005 ℃ in the controlled temperature range and meets the need for accuracy in rangefinder system.