Refractive Index Measurement Based on Blazed Fiber Bragg Grating

张键,刘波,金龙,徐玲玲,开桂云
IF: 0.6
2008-01-01
ACTA PHOTONICA SINICA
Abstract:A new method for measuring refractive index based on blazed fiber Bragg grating was demonstrated.Took SLED as the source,the measurement of the refractive index is dependent on the measurement of the transmission power of the blazed fiber Bragg grating.When the refractive index is changed between 1.372 3 and 1.453 2,the transmission power of the blazed fiber Bragg grating is decreased from 0.611 mW to 0.472 mW linearly and the sensitivity reaches 1.718 μW/(0.001 index changed).The method has the characteristic of simpleness,high sensitive and it will have a good future on index measurement.
What problem does this paper attempt to address?