ANALYSIS OF HYDROXYBENZENE AND QUINONE BY HPLC AND GC IN SYNTHESIS OF HYDROQUINONE

Jianbin Zhang,Guohua Chen,Wei Song,Pengyan Zhang,Lingwei Zhang,Xionghui Wei
DOI: https://doi.org/10.3969/j.issn.1003-9384.2008.05.019
2008-01-01
Abstract:High performance liquid chromatogram(HPLC)and gas chromatogram(GC)methods were used to determine the concentrations of the compositions in the synthetical process of hydroquinone. In the HPLC performance,the Kromasil C18 was used as the separating column,injection loop was 20 L,and the flow phase was methanol:deioned water:transparent additive=20:80:0.15.The separation conditions of HPLC were as follows:the flow rate of the mobile phase was 1 mL/min and samples were detected by the Prostar UV-deteetor at the wavelength of 254 nm to determine low con- tents of hydroquinone,benzonquinone,catechol,and phenol.GC method was used to determine high contents of above compositions by the flame ion detector(FID).
What problem does this paper attempt to address?