Experimental Research of Heating and Refrigeration of Solar Cooling Tube

Xiao-dong MA,Zhen-yan LIU,Hui-zhong ZHAO
DOI: https://doi.org/10.3321/j.issn:1006-2467.2007.12.003
2007-01-01
Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University
Abstract:This paper presented the structure and experimental study of a solar cooling tube. The solar cooling tube consists of four major components: solar collector, adsorbent bed, condenser and evaporator all in one glass tube. It chooses the zeolitel3X-water as working pair and is environmental friendly. To evaluate its heating and refrigeration performance, an experiment was conducted on a typical day: total solar energy to the solar adsorption cooling tube is about 23.5 MJ/m 2, a solar cooling tube is capable of heating 4 kg of water to about 50°C in daytime and 4 kg of water to about 39°C at night, as well as producing a refrigeration capacity of about 276 kJ. Its coefficient of performance can reach 0.22.
What problem does this paper attempt to address?