Seismic overstrength factors for reinforced concrete frames

Jing ZHOU,Jian CAI,Xiao-dan FANG
DOI: https://doi.org/10.3969/j.issn.1007-6069.2007.04.040
2007-01-01
Abstract:Based on 14 multistory reinforced concrete frames of various seismic characteristics, this paper assesses, by means of inelastic static pushover analysis, the seismic overstrength capacity of the frames designed according to china's code for seismic design of buildings. In analysis, the lateral force profile is designated proportional to the lateral equivalent horizontal load distribution specified in the seismic code and increases monotonically, and the individual two-dimensional frame is employed to analyses the structural overstrength capacity. Analysis results indicate that the overstrength factor is predominantly influenced by seismic fortification intensity; the overstrength factor also depends strongly on the infill wall, the overstrength factor of the frames with infill wall is clearly larger than that of the frames without infill wall. Similarly, the overstrength factor of interior frames is commonly greater than that of exterior frames, moreover the overstrength factor is decreased as the number of stories is increased.
What problem does this paper attempt to address?