The Experimental Study on the Axial Solids Suspension Characteristics in Slurry Bubble Column

Yifeng Su,Jianhui Li,Qinghua Zeng,Yifei Wang,Zunhong Yu
DOI: https://doi.org/10.3969/j.issn.1001-7631.2007.03.008
2007-01-01
Abstract:The characteristics of the axial solids distribution in a slurry bubble column was studied experimentally. The radiant office gas distributor and internals were set in the slurry bubble column to distribute the gas uniformly and optimize the suspension effect of solids. The experiments were carried out in the air-water-glass beads system. The their effects on the uniform distribution of solid concentration were investigated as the initialized solid holdup was from 0 to 30% and the superficial gas velocity was from 1 cm/s to 25 cm/s and the liquid circulating rate was 0-230 L/h. Moreover, based on the uniformity of solid axial distribution, the respective performances of the radiant orifice gas distributor and the perforated plate (1 mm) were compared, as well as with and without internals. The experimental results indicated that in evidence the performances of the radiant orifice gas distributor apparent exceeded the perforated plate's (1 mm) and with internals also exceeded without internals under high superficial gas velocity. Furthermore, as a result, the gas velocity with 10 cm/s was suitable for the reactor. The optimum circulating ratio was from 80 L/h to 150 L/h. And the critical gas velocity for complete solids suspension was from 10 cm/s to 12 cm/s, on which the effect of catalyzer quantity was not remarkable.