Real-time measurement of unstable concentration distribution near interface for gas-liquid cocurrent absorption

Ying GUO,Xi-gang YUAN,Ai-wu ZENG,Guo-cong YU
DOI: https://doi.org/10.3969/j.issn.1005-9954.2007.01.002
2007-01-01
Abstract:Experimental data of the concentration field near free gas-liquid interface with high spatiotemporal resolution is important for the comprehension of mass transfer kinetics. The real-time laser holographic interferometry was used to investigate respectively the evolutions of concentration distributions going with absorptions of CO2 by ethanol and methanol for cocurrent flow. The results show that the instability phenomena in the liquid exist universally during mass transfer. It mainly includes two forms of near-interface turbulence and periodic burst. And the steady-state CO2 mass fraction distributions inside the liquid phase close to the interface gained under different conditions demonstrate that mass fraction fluctuation is nearly relational to the mass transfer impetus affected by the physics property and velocity of the absorbent.
What problem does this paper attempt to address?