Investigation on Condensation Heat Transfer Outside Corrugated Tube

DANG Gao-jian,LUO Yu-shan,CHEN Ting-kuan,WANG Hai-jun
DOI: https://doi.org/10.3969/j.issn.1005-9954.2007.12.006
2007-01-01
Chemical engineering
Abstract:An experimental investigation on the condensation heat transfer of water and kerosene outside corrugated tube was carried out.The sleeving heat exchanger whose inside tube is corrugated tube was used in the experiment.It was placed in both horizontal direction and vertical direction.At different velocities of flow,the condensation heat transfer coefficient of corrugated tube was calculated based on the experimental data.And it was compared with the theoretical calculation value(based on the same temperature and velocity of flow) of smooth tube.The results show that as the liquid-film Reynolds number increases,the condensation heat transfer coefficient increases;and the condensation heat transfer coefficient of corrugated tube is greater than that of smooth tube.The corrugated tube improves the condensation heat transfer outside tube.This improvement of corrugated tube for water is more obvious than that for kerosene.
What problem does this paper attempt to address?