Study on Characteristics of 600 MW Directly Air Cooled Units Under Variable Operating Conditions

Lan-xin ZHOU,Jing YANG,Xiang-liang YANG
DOI: https://doi.org/10.3321/j.issn:1000-6761.2007.02.004
2007-01-01
Abstract:Taking 600 MW directly air cooled units as an example,a mathematical system model of directly air cooled units under variable operating conditions has been elaborated,considering pressure and heat dissipation loss of the exhaust pipe,as well as the pressure difference between burbine exhaust and condenser entrance,caused by the steam column concerned.Characteristic curves of directly cooled units' cold end system were then program calculated and the effects on the set's characteristics,caused by varying condenser pressure,as well as exhaust pipings pressure loss,were analyzed,which may all serve as a reference for operating air cooled units economically.Figs 7,tables 2 and refs 7.