Thermo-Flow Performances for the Main-Auxiliary Integrated Natural Draft Dry Cooling System
Zongyang Zhang,Yichen Hou,Hanyu Zhou,He Jia,Lei Chen,Yanqiang Kong,Weijia Wang,Lijun Yang,Xiaoze Du
DOI: https://doi.org/10.1007/s11630-024-1937-9
IF: 2.013
2024-02-04
Journal of Thermal Science
Abstract:Recently, natural draft dry cooling system with the main-auxiliary integrated air-cooled heat exchangers in the up and lower layers, has drawn attention to the electric power industry. This research firstly develops two physical models for the integrated cooling system, namely Case A and Case B. In Case A, the main air-cooled heat exchanger is arranged in the upper layer and the auxiliary air-cooled heat exchanger arranged in the lower layer, while in Case B, the two heat exchanger systems are arranged in the opposite way. And then, directing at the engineering TMCR and TRL 1 working conditions, the unit-local-overall thermo-flow characteristics of Case A and Case B are obtained and compared by numerical simulation. The findings show that, for the auxiliary air-cooled exchanger, Case A has obviously higher cooling performances than Case B, with the difference varying from 5.46% to 7.55%. Whereas, for the main air-cooled exchanger, Case B shows the recovered cooling performances, with the difference changing from 1.15% to 2.99%. Case A is preferably recommended to the engineering application in consideration of more strict cooling demand of the auxiliary cooling system. Conclusively, this research will provide some theoretical guidelines for the design and construction of the main-auxiliary integrated natural draft dry cooling system.
engineering, mechanical,thermodynamics