Compensation Control of Matrix Converter for Abnormal Working Conditions

SUN Kai,HUANG Lipei,MATSUSE Kouki
DOI: https://doi.org/10.3321/j.issn:1000-0054.2007.07.002
2007-01-01
Abstract:Safe and stable operation of matrix converters during abnormal grid voltage conditions can be ensured by a feed-forward compensation strategy based on indirect space vector modulation.A virtual dc link voltage of the matrix converter is calculated by measuring input grid voltages,with the space vector modulation index adjusted in real-time according to the variation of the virtual dc link voltage so that the output voltages and currents can be maintained at normal values.Tests were carried out on a matrix converter prototype.Compared with operation without compensation,the harmonic components of the output currents are reduced by more than 45% for unbalanced grid voltages and output currents are maintained steady during grid voltage sags.