Research of optimal parameter of fluid-jacket heater and depression of gas consumption

TANG Jian-feng,LI Yu-xing,XUE Ji-ming,PAN Min-yong
DOI: https://doi.org/10.3321/j.issn:1000-5870.2007.05.016
2007-01-01
Abstract:The main function of fluid-jacket heater in the gas accumulating flow is to prevent the hydrate that forms in the throttle choking the pipeline when pressure drop of natural gas appears. Because of low operating level of field, the exit temperature of fluid-jacket heater is much higher than the highest formation temperature of hydrate to prevent the forming of hydrate. But it could waste a lot of heat energy and consequently increase the gas consumption of the fluid-jacket heater. A set of methods and models were established, which are used to calculate the reasonable heating temperature of fluid-jacket heater and the quantity of gas consumption. The operation of all fluid-jacket heaters in Zhongyuan Oilfield was calculated and analyzed. Running schemes of vary seasons', the heating temperature required and gas consumption per year were established. Using this scheme, not only the gas consumption of the heater but also the operating temperature of the separators can be depressed so that it can depress the hydrate and water dew point, reduce the accumulating condensate in the gas pipelines, improve the efficiency of pipe transmission and reduce the times of cleaning pipe and thus gain much benefit.
What problem does this paper attempt to address?