Abstract:The primary objective is to study the effect of high-modulus PVA fibers on improving the seismic performance of super-high-strength concrete short columns with high axial pressure ratio. Specimens with the concrete strength ranging from 103.6 to 112.1 Mpa and a shear span ratio of 2.0 were manufactured. The high modulus PVA fibers were added with the volume fractions of 0.17%, 0.33% and 0.5%. The specimens were subjected to low cyclic reversed lateral load to simulating simple supported beams. The cracking and damage process of the specimens were studied, the failure patterns and hysteretic behavior of short column specimens with different PVA fiber volume fractions analyzed, and the initial cracking load and the maximum load for the short columns determined. The test results indicate: under high axial load, the specimen without PVA fibers exhibited brittle shear failure with poor ductility. However, with increase in the fiber volume fractions, flexure-shear failures with certain ductile characteristics were observed, and both the crack load and the maximum load greatly enhanced greatly by 12.8%-31.1% and 13.2%-29.9%, respectively. The seismic ductility was also improved greatly, with the displacement ductility and the drift ratio of the specimens being improved by 12.8%-31.1% and 13.2%-29.9%, respectively. Minimum PVA fiber volume fractions that can satisfy certain seismic requirement on displacement ductility and drift ratio were put forward.