Simulative study on hybrid control of shunt active power filter

Gang LI,Chen SHEN,Qian-zhi ZHOU
DOI: https://doi.org/10.3969/j.issn.1006-6047.2007.10.014
2007-01-01
Abstract:For the control methods of shunt APF (Active Power Filter), the hysteresis control has faster response and less influence of load parameter variation, but unfixed switching frequency and worse stability of DC voltage, while the SVPWM (Space Vector Pulse Width Modulation) control has higher DC voltage utilization ratio and better DC voltage stability, but more influence of load parameter variation on its performance. A hybrid method combining the space voltage vector control and the fixed frequency hysteresis control is used to control the output current of APF. The SVPWM control, the single-phase and three-phase fixed-frequency hysteresis control and the hybrid control are analyzed and simulated with PSCAD/EMTDC. Results show that the hybrid method has better static stability and quicker dynamic response.