Accurate Measurement Of Trace Selenium In Fish By Isotope Dilution Multiple Collector Inductively Coupled Plasma-Mass Spectrometry With Hexapole Collision Cell

Jun Wang,Liu Cong-Qiang,Hai Lu,Chao Wei,Tao Zhou
DOI: https://doi.org/10.3321/j.issn:0253-3820.2007.06.007
IF: 1.193
2007-01-01
Chinese Journal of Analytical Chemistry
Abstract:The method of isotope dilution multicollector ICP-MS with hexapole collision cell was developed to determine trace amount of Se in fish through the studies of the use of collision gases, SeH calibration, mass bias calibration, matrix effect and sample preparation. Furthermore, this method was used to measure trace Se in salmon fish for the comparison among the National Metrology Institutes Organized by International Committee for Weight and Measures-Consultative Committee for Amount of Substanee-Metrology in Chemistry (CIPM-CCQM). The measured result of this work is 7.38 +/- 0.22 (mu mol/kg), which is in agreement with the certified value 7.32 +/- 0.28 (mu mol/kg). Thus the reliability and accuracy of the method established in this work are validated.
What problem does this paper attempt to address?