Determination of Azithromycin in Human Plasma by HPLC-MS and Its Relative Bioavailability

Yu-hua WANG,Jun-jie CHEN,Ben-mei CHEN,Bi-kui ZHANG
DOI: https://doi.org/10.3321/j.issn:1001-2494.2006.01.016
2006-01-01
Abstract:OBJECTIVE: To determine azithromycin in human plasma by a HPLC-MS method, and to study its relative bioavailability. METHODS: Azithromycin concentrations in plasma were determined by HPLC-MS. The test and reference formulations of azithromycin were given to 18 healthy male volunteers. Bioequivalence was determined by a two one-side t-tests. RESULTS: The calibration curve was linear within the range of 2.5-800 μg·L-1 (r = 0.9993), the recovery was 98.1%, the RSDs of intra- and inter-day were no more than 11.3% and 8.6%. After a single oral dose of 500 mg azithromycin test or reference dispersible tablet, the main pharmacokinetic parameters were as follows: AUC0-120 (5 856.5 ± 1 423.6) and (6 096.8 ± 1 111.0) μg·h·L-1, ρmax (520.1 ± 94.1) and (558.8 ± 74.0) μg·L-1, tmax(1.4 ± 0.4) and (1.3 ± 0.2) h, t1/2(36.1 ±10.2) and (36.2 ± 11.7) h, respectively. Relative bioavailability was (96.3 ± 16.0)%. CONCLUSION: The method is accurate and sensitive with no endogenous interference. No significant difference exists among the main pharmacokinetic parameters for the test tablets and the reference tablets. The two formulations are bioequivalent.
What problem does this paper attempt to address?