Structure damage indicator based on time domain correlation analysis

Jinghong Xue,Minzheng Zhang
DOI: https://doi.org/10.3969/j.issn.1000-1301.2006.02.010
2006-01-01
Abstract:A structure damage indicator based on time domain correlation analysis is expatiated. Experiment of this indicator is done for the purpose of exploring a damage identification method which is subitale to little damage. The experiment model is a 2-floors steel frame with four columns. The model is settled in soil through four piles. Damage slots are made at the top of the first floor columns and two damage conditions are considered. The first order frequency change percentages, 0.42 percent and 0.94 percent, are calculated through numerical simulation. The model bottom is excited by an exciter which gives 25 HZ sinusoidal excitation. The indicator is calculated by using top and middle floor response and the indicator's change percentage curves with the damage degree are plotted. The result of experiment shows that the indicator is sensitive to damage and it has the potential to judge and evaluate the structure damage.
What problem does this paper attempt to address?