Lidar for Monitoring Sodium Layer of Atmosphere

LIU Xiao-qin,HU Shun-xing,LI Chen,HU Huan-ling,ZHANG Yin-chao,DOU Xian-kang
DOI: https://doi.org/10.3969/j.issn.1003-501x.2006.09.001
2006-01-01
Abstract:A new sodium resonance fluorescence lidar is set up, which is for measurements of Sodium density by resonance fluorescence method over 80~110km altitude. A Dye laser, which emits laser pulse with 77mJ pulse energy at wavelength 589nm, pumped by Nd:YAG laser, and 1m aperture receiving telescope are used to achieve the desired performance levels in the lidar system. This paper presents structures of the lidar system and technologic characters of system such as self-aligned, wavelength corrected and signal acquisition. At last, the field test results are reported and analyzed.
What problem does this paper attempt to address?