Corrosion monitoring of PC beams with a novel type of HCFRP sensors

C. Q. Yang,Z. S. Wu,L. P. Ye
2006-01-01
Abstract:In this contribution, the corrosion monitoring function of PC structures is demonstrated using a novel type of hybrid carbon fiber reinforced polymer (HCFRP) composite sensors. The HCFRP sensors are designed to consist of three types of carbon tows of different strength and moduli as active materials. The HCFRP sensors with different gauge lengths are mounted on PC tendon, steel bar, and embedded in compressive and tensile sides of the PC beam to monitor the corrosion of PC tendons. To accelerate the corrosion, a distinct current of 3 A is introduced into one PC tendon of the PC beam, and the tests are performed under a load of about 54 kN. The experimental results show that the corrosion of PC tendon can be effectively monitored both in tensile and compressive sides. For the sensors embedded in tensile side of the PC beam, the electrical resistance increases as corrosion progresses; while for those embedded in compressive side, the electrical resistance decreases with corrosion time. Moreover, it is shown that the electrical behaviors of the zones where the corrosion is performed are much different from those of the other zones. In these zones, either there exist jumps in electrical resistance, or the electrical resistance increases with a much larger increasing rate than those of the other zones. Thus, a distributed corrosion monitoring function of PC beams is demonstrated.