A NEW ACTIVE SENSING DEVICE FOR WIRELESS TELEMETRY- BASED STRUCTURAL HEALTH MONITORING

Seunghee Park,Benjamin Grisso,Daniel J. Inman,Chung-Bang Yun
2006-01-01
Abstract:This study presents an experimental study using an active sensing device, which consists of a miniaturized impedance measuring chip (AD5933) and a self-sensing macro-fiber composite (MFC) patch, to detect corrosion may occur in aluminum structures widely used for aerospace, civil and mechanical systems. A simple beam structure made from a 6063 T5 aluminum alloy was selected for corrosion detection testing. Four different corrosion cases with two different locations and two different degrees at each location were artificially inflicted on the beam by using hydrochloric (HCI) acid. In order to identify the degrees and locations of the corrosion, the electro-mechanical impedance-based damage detection technique using the proposed active sensing device was investigated. Root mean square deviation (RMSD) metric of the real part of the impedances obtained from the MFC patch was selected as a damage-sensitive feature. Experimental results have verified that the proposed approach can be an effective tool for detection and quantification of corrosion in aluminum structures.
What problem does this paper attempt to address?