Distribution of Electromagnetic Field in Cold Crucible for Electromagnetic Confinement

Ruirun Chen,Hongsheng Ding,Weisheng Bi,Jingjie Guo,Lin Liu,Hengzhi Fu
DOI: https://doi.org/10.3321/j.issn:1001-2249.2006.10.003
2006-01-01
Abstract:Distribution of magnetic strength is measured by the small induction coil method. The results show that the magnetic strength is higher inside the coil, and then is attenuated toward both ends. Axial magnetic intensity increases with the increases of the power, and decreases with the decrease of the radial, slightly decreasing from the slit to the middle of the segment. Radial magnetic intensity is sharply decreased with increasing in radius and coils. Axial magnetic intensity is higher than radial magnetic intensity, and is more important for electromagnetic confinement.
What problem does this paper attempt to address?