Cyclic lateral loading test on a sub-structure model of the National Swimming Center

Qian Jiaru,Hu Xiaobin,Zhao Zuozhou,Fu Xueyi,Gu Lei
DOI: https://doi.org/10.3321/j.issn:1000-131X.2006.09.001
2006-01-01
Abstract:To study the seismic behavior of the heavily loaded part of the internal wall of the National Swimming Center, the so called“Water Cube”, an experiment was conducted on a one-third scaled sub-structure model subjected to representative gravity load and cyclic lateral load. Damage of the sub-structure model are in the forms of local buckling and tension fracturing of the base metal of the structural members, and most of the damaged members are at the wall surfaces. Due to the cover plates welded at member ends, the plastic hinges and the damage locations are away from the connections between the members and the joints, thus brittle failure of the weldments is avoided. The nominal yield top drift ratios of the model under push and pull forces are about 1/127 and 1/100, respectively, and the corresponding strength is in the range between 880kN and 746kN, 1.73 and 1.47 times that of the representative gravity load of the model, respectively. The lateral load is 2 times that of the representative gravity load and the top drift ratio is about 1/50, whereas the strength of the model is less than the maximum strength while the lateral displacement may increase further. The sub-structure model exhibits high load-carrying, deformation and energy dissipation capacities.