Wind load factor and parametric analysis of long-span single-layer spherical reticulated shell

Qingxiang LI,Wenjuan LOU,Shichao YANG,Bingnan SUN
DOI: https://doi.org/10.3321/j.issn:1000-6869.2006.04.010
2006-01-01
Abstract:Using three-dimensional FEM, wind-induced dynamic response of a project designed with single-layer spherical reticulated shell scheme, was analyzed to obtain vertical wind load factors of 24 wind angles. The worst wind angle was identified by using data from wind tunnel test and the analysis. Due to the fact that there exists not only vertical wind-induced vibration but also horizontal wind-induced vibration, leeward and crosswind load factors are calculated at disadvantage angles. The results of parametric analysis for different cases indicate that wind load factor varies obviously with wind angle, which should be considered in wind resistance design. For single-layer spherical reticulated shell, diagonal braces can significantly reduce wind load factor, however the boundary conditions have little effect. The wind load factor has some reduction as the damping ratio increases. The damping ratio has a larger effect on vertical wind load factor than horizontal wind load factor. These conclusions contribute to the wind-resistance design and disaster prevention analysis of reticulated shell structures.
What problem does this paper attempt to address?