Wire-Mesh Capacitance Tomography of Two-Phase Flows in a Horizontal Tube

黄善仿,张修刚,王栋,林宗虎
DOI: https://doi.org/10.3969/j.issn.1001-2060.2006.04.021
2006-01-01
Abstract:A wire-mesh capacitance tomography of two-phase flow distribution is presented.Thermocouple wires with an insulation film on their surface are used as capacitive transducers.The electrolyte of the capacitor is an insulation film with the two poles being respectively metal cores of thermocouple wires and electroconductive fluid film covering the surface of thermocouple wires.The capacitance is directly proportional to the length of the electroconductive fluid film and independent of the latter's distribution and shape.The wire-meshes are parallel and uniformly arranged on a pipeline section.The inner diameter of the test pipeline is 70 mm and the capacitance of each mm long mesh wire being used is 4.82 pF with the spacing of mesh wires being 4 mm.The measurement was performed by use of horizontal and vertical two-direction capacitive transducers.On the basis of knowledge about flow patterns,it is not necessary to reestablish algorithm and the phase distribution can be readily obtained.The steady-state tests show that with this method one can realize the reestablishment of flow patterns,and the section water content as calculated based on the foregoing has a maximal error of 3.9%.