Study on the residual gas in all-glass evacuated collector tubes
XiaoWen Zhou,Zhiqiang Yin,Guangjun Dong,Shimin Zheng
2005-01-01
Abstract:The vacuum plays a very important role in heat loss and the lifetime of all-glass evacuated collector tube. A vacuum opener has been made, which connects to the high vacuum system for opening collector tubes. The vacuum degree between the cover and inner glass tube, and the composition of the residual gases were studied using electronic control unit (ECU). One collector tube was operated 12 years in the solar water heating system, which incorporates a flashed getter, has been studied, the vacuum pressure of the collector tube is about 1.3E-2Pa. The collector tube has low heat loss and high stagnation temperature due to the appropriate vacuum degree in the tube. The main residual gases of all-glass evacuated collector tubes include H2, He, CH4, H2O, CO, N2, NO, O2, Ar and CO2. It is also estimated that the penetration rate of helium is reduced as the tube filled water.