Measurement and Analysis of Automatic Firing Gun-man System Mechanical Admittance

BAO Jian-dong,WANG Chang-ming,KONG De-ren,HE Yun-feng
DOI: https://doi.org/10.3969/j.issn.1005-9830.2006.04.029
2008-01-01
Abstract:This paper makes an electronic measuring system of shoulder' s receiving force and gun-shoulder movement of gun-shoulder system in view of characteristics of standing non-rest firing accuracy. The mechanical admittance function of gun-shoulder system is procured by using electronic measuring data. The models are identified for the admittance functions of gun-shoulder system by a-dopting an orthogonal component method. The main differences of the automatic weapon between passive state and initiative state are discussed. The results show that there are some differences between stiffness, quality and damp and that the diversification law of the curve and the frequency of each apex are identical.