Torsional strength of steel-concrete composite box girders
Nie Jianguo,Tang Liang,Hu Shaowei,Zhu Hongchao
DOI: https://doi.org/10.3321/j.issn:1000-131X.2008.01.001
2008-01-01
Abstract:Nine steel-concrete composite box girders,four under pure torsion and five under combined bending and torsion were tested to study their torsional behaviors.Tests results showed that the composite box girder resists external torque by two mechanisms: one is the composite box section comprising U-joist and concrete flange,the other is the equivalent box section which is developed in the cracked concrete flange.And the composite action between joist and concrete flange definitely exists in the composite girder subjected to torsion.The contribution of U-joist lies that it carries considerable torque as a part of the composite box section,as well as restrains concrete flanges from deforming longitudinally.According to test results,using the rotating-angle softened truss model(RA-STM),a three-dimensional behavioral truss model cable of analyzing the torsional strength of such girders under combined bending and torsion,is presented.This model,which satisfies the equilibrium equations,compatibility equations and the constitutive laws of materials,can accurately predict the torsional strength of specimens.Additionally,the interaction between bending and torsional strengths is discussed.