The Measurement and Calculation of Heat Transfer Coefficient under Different Cooling Conditions

YUAN Jian,ZHANG Wei-min,LIU Zhan-cang,CHEN Nai-lu,WANG Ming-hua,XU Jun
DOI: https://doi.org/10.3969/j.issn.1009-6264.2005.04.029
2005-01-01
Abstract:In order to determine the heat transfer coefficient under different cooling conditions, an experiment apparatus is designed to measure the cooling curves of air, water and different-pressure air spray cooling. A 120mm×120mm×20mm flat sample, proved to be one-dimension heat conduction by finite element method(FEM), is adopted for the measurement in this experiment. Both the Inverse Heat Conduction Method (IHCM) and Lumped Heat Capacity Method (LHCM) are used in the calculation of heat transfer coefficient. The results of air spray cooling are also discussed based on different pressures. The experiment results indicate that LHCM is applicable only when Bi0.1 and also indicate that during air spray cooling, the higher the pressure is, the greater the heat transfer coefficient is.
What problem does this paper attempt to address?