Accurate Flux Observer Based on Distributed Multi-Processor in MV Adjustable Speed Drive System

S Liu,JZ Liu,ZM Zhao,LQ Yuan,H Bai,HT Zhang
DOI: https://doi.org/10.1109/icems.2005.202730
2005-01-01
Abstract:This paper presents an accurate flux observer used in distributed multi-processor (DMP) adjustable speed drive systems. The stator flux linkage is estimated with a full-order observer, while the rotor speed is identified by using Lyapunov theorem. In order to improve the system performance in a wide speed range, the stator resistance is estimated simultaneously. In this paper, the structure of the DMP system, the principle of the full-order observer and the method for identifying the rotor speed and state resistance are all described in details. Relevant simulation results based on MATLAB/SIMULINK are given to prove the performance of the method. Experiments of a real system also verify the feasibility of this scheme
What problem does this paper attempt to address?