The Use of Magnesium Ion Method for the Determination of Droplet Quantity Entrained by Flue Gas at the Outlet of a Demistor

李森,周屈兰,徐通模,惠世恩
DOI: https://doi.org/10.3969/j.issn.1001-2060.2005.04.011
2005-01-01
Abstract:Based on the technological features of the desulfurization by wet limestone-gypsum method the authors have revealed through a study that Mg2+ concentration in slurry is equal to the concentration of Mg2+ in the droplet entrained by the flue gas at a demister outlet. On the basis of this conclusion a constant speed sampling was performed at the demister outlet with 5m3 of flue gas being extracted. On the basis of a determination of the Mg 2+ concentration in a micro-fiber filter wash liquid in the sampling system, in a sampling-tube wash solution and in a blank micro-fiber filter wash liquid, as well as the slurry density in an absorption tower and the concentration of Mg 2+ in an absorption-slurry filtering liquid, calculated was the liquid droplet quantity entrained by the flue gas at the demister outlet.
What problem does this paper attempt to address?