Degradation of 4-chlorophenol (4-CP) by Fenton reagent improving dual-low frequency ultrasound technology

赵德明,史惠祥,雷乐成,汪大翚
DOI: https://doi.org/10.3785/j.issn.1008-973X.2004.01.023
2004-01-01
Abstract:4-Chlorophenol solution was treated by Fenton reagent improving dual-low frequency ultrasound technology, and the major affecting factors such as sound intensity, initial pH, initial concentration, medium temperature and the sorts of saturating gas were studied. Experimental results show that ultrasonic intensity and initial pH alter noticeably the reaction rates, with preferable operating conditions as low pH, 20-40 ℃,22 kHz ultrasound intensity of around 15 (W·cm)~(-2),constant 40 kHz ultrasound intensity,H2O2∶Fe~(2+)(molar ratio) of about 20∶1,the addition amount of H2O2 of about (0.3-0.5)×10~(-3) and use of abundant oxygen as saturating gas. The addition of Fenton reagent can increase the 4-CP removal rate, which obeys first-order kinetic law. After treatment, the enhancement of the 4-CP removal rate is around 130%. Therefore, the synergetic effect of Fenton reagent improving dual-low frequency ultrasound technology is obvious.