[Anticoagulation in Chinese Patients with Carbomedics Mechanical Prosthetic Heart Valves].

Wei Zhuang,Xin-Min Zhou,Jian-Guo Hu,Jian-Min Li,Jie-Feng Yu,Ling Jiang,Dong-Xu Hu
DOI: https://doi.org/10.3321/j.issn:1672-7347.2004.04.024
2004-01-01
Abstract:OBJECTIVE:To provide some references for defining the Chinese optimal intensity of anticoagulation after mechanical heart valve prostheses replacement.METHODS:For the 178 patients with carbomedics mechanical prosthetic heart valves, the means of INR were compared between the patients with complications and those without complications at the standard of INR1. 4 - 2.0. Also, the variations of INR were compared among different follow-ups.RESULTS:During the follow-up, 22 hemorrhagic and 1 thromboembolic complication occurred. The total linearized rate of anticoagulation-related hemorrhage was 5.83% pty. The total linearized rate thromboembolism was 0.26% pty. The late mortality was 0.79% pty (3 cases ). The final mean INR was 1.68 +/- 0.38. The final mean oral warfarin dose was 2.34 +/- 0.80 mg. The differences of variations of INR in five periods were significant (F = 5.072, P < 0.05). The mean INR in the first month of follow-up was 1.75 +/- 0.27.CONCLUSION:For Chinese patients with mechanical prosthetic heart valve, hemorrhage is the principal complication, the ratio of which is much higher than that of thromboembolism. The low-dose anticoagulation (INR1. 4-2.0) could remarkably decrease hemorrhagic events as effectively as prevent the thrombolic events. Moreover the INR is the most unstable in the first month of follow-up, so re-examination for the patients in the first month after the operation is vitally important.
What problem does this paper attempt to address?