Analysis of stresses and displacement for roller compacted concrete arch dam on a weak foundation

陈强,刘光廷,李鹏辉
DOI: https://doi.org/10.3321/j.issn:1000-0054.2004.03.042
2004-01-01
Abstract:A roller compacted concrete arch dam is over 100 m high and the foundation is weak, the deformation and stresses in the arch dam were much larger than normal, especially the abutment displacement downstream. A 30 m long stift pier was added to reinforce the abutment and reduce the deformation. Three-dimensional analyses of the stresses and displacement due to the hydraulic pressure showed that the downstream tensile stresses in the arch darn were reduced by 50% and the deformation was reduced by 20%. The stresses in the foundation near the dam abutment were transmitted mainly through the pier, which enlarged the dam foundation and reduced the sinkage. Since the pier reduces dam span and improves its rigidity, the piers share the load on the darn abutment which reduces the stresses so the deformation is controlled.
What problem does this paper attempt to address?