Alarm On Volatile Organic Compounds In The Atmosphere With Principal Component Analaysis-Linear Discriminat Analysis
LanPing Hu,Zhang Lin,Li Yan,Zhang Li-Ming,Junde Wang
DOI: https://doi.org/10.3321/j.issn:0253-3820.2007.03.007
IF: 1.193
2007-01-01
Chinese Journal of Analytical Chemistry
Abstract:The system, which contained one to six components including acetone, methylene chloride, toluene, benzene, chloroform and methanol, was analyzed qualitatively with the combination of principal component analasis-linear discriminate analysis( PCA-LDA) and remote sensing FTIR technique. There are FTIR spectra overlap ped seriously each other for the six an, toxic organic compounds selected, The prediction results of PCA-LDA and BP-ANN were compared. The ratio of correct. recognition ratio, recognition ratio and error recognition ratio of PCA-LDA were 92. 2%, 94. 4% and 7.8% respectively. The corresponding values of BP-ANN were 91.1 %, 95.6% and 8. 9%, respectively. The results demonstrated that limitations of LDA were overcome with PCA and then the performance of LDA was improved by PCA. The prediction performance of PCA-LDA was comparable to BP-ANN. Considering time-consuming and fussy operation of BP-ANN, PCA-LDA was determined as the suitable method for the alarm on volatile organic compounds in the atmosphere.