On-line diagnosis of abnormal conditions of air separation process by dynamic PCA

Wang Jingyuan,Shao Zhijiang,Ji Peng,Yao Ketian,Chen Zhiqiang
DOI: https://doi.org/10.3969/j.issn.1001-4160.2010.01.001
2010-01-01
Abstract:On-line diagnosis of abnormal conditions of the air separation process is of great practical value to ensure product qualities,reduce the incidence and the loss of failures,such as 'Nitrogen blockage'.As a data-driven modeling method,Principle Component Analysis(PCA) has been widely used for complex industrial process monitoring and fault diagnosing.Since the static PCA can not catch the dynamic information of the real industrial data,Dynamic Principal Component Analysis(DPCA) is introduced as an extension of PCA for dealing with multivariate dynamic data.Determining the necessary number of time lags is an important step in DPCA.This paper applies the DPCA on the air separation process,building an abnormal condition on-line diagnosing system. Dealing with the characteristics of fault diagnosis of air separation process,a method for determining the time lags is introduced.The actual operating results,in which the warn-rate of the diagnosing system to the faults of the process is 100%and the false-warn rate is about 4%,proved the validity of the proposed diagnosing system and the effectiveness and feasibility of the proposed method of determining the time lags of DPCA.
What problem does this paper attempt to address?