The Effect of Flow Field and Fuel Spray of Combustor with Swirl Cup on Lean Blowout Limit at Idle Condition

袁怡祥,林宇震,刘高恩
DOI: https://doi.org/10.3969/j.issn.1000-8055.2004.03.009
2004-01-01
Abstract:Two kinds of combustor domes were investigated, one with three swirlers (model A), and the other with two swirlers (model B). Flow field and fuel spray of these models were measured by phase Doppler analysis. The lean blowout fuel air ratio and flame photo were obtained. The results show that model A has better Sauter mean diameter and uniformity than model B, but model A has worse lean blowout performance. The flow rate in the inner swirler of model A must be decreased to establish a low pressure stagnation region which would be helpful to the improvement of lean blowout fuel air ratio.
What problem does this paper attempt to address?