DESIGN OF ON-LINE MONITORING SYSTEM OF TURBINE CAVITATION

蒲中奇,张伟,施克仁,吴玉林
DOI: https://doi.org/10.3321/j.issn:1000-1026.2004.21.013
2004-01-01
Abstract:Current turbine cavitation on-line monitoring systems use narrowband signal process, which have only one channel and no on-board signal process. Hence the precision of cavitation testing of the systems is low and the systems are not fit for cavitation space allocation. An on-line cavitation monitoring system is presented. The frequency band of the system is 1 Hz-500 kHz, which improves the precision of the cavitation testing; the system uses eight channels, which is fit for cavitation space allocation; the system adopts on-board signal process based on DSP, which improves the ability of signal process. The system was used in the cavitation model experiments. It was found that root mean square of the accelerometer and acoustic signal each improves with the reduction of cavitation number. Therefore, accelerometer and acoustic signal can both be used in testing cavitation and acoustic signal is more reliable. At the same time, it was pointed that power of high frequency component of acoustic signal gets a prominent extremum, which is instructive for testing incipient cavitation.
What problem does this paper attempt to address?