[Determination of Adefovir in Monkey Plasma by Liquid Chromatography-Tandem Mass Spectrometry].

Li-yan Zhao,Xiao-yan Chen,Yong Zhang,Han-yu Yang,Da-fang Zhong
DOI: https://doi.org/10.3321/j.issn:0513-4870.2003.02.010
2003-01-01
Abstract:AIM:To develop a sensitive and specific liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for the determination of adefovir in monkey plasma.METHODS:Adefovir and internal standard 9-(3-phosphonylmethoxypropyl) adenine were isolated from plasma by protein precipitation with methanol, then chromatographed by using a Diamonsil C18 column. The mobile phase consisted of methanol-water-formic acid (20:80:1). Electrospray ionization (ESI) source was applied and operated in the positive ion mode. Selected reaction monitoring (SRM) mode with the transitions of m/z 274-->m/z 162 and m/z 288-->m/z 176 were used to quantify adefovir and the internal standard, respectively.RESULTS:The linear calibration curve was obtained in the concentration range of 0.02-4.00 mg.L-1. The lower limit of quantitation was 20 micrograms.L-1. The inter- and intra-day precision (RSD) was less than 5.8%, and the accuracy (relative error) was within +/- 4.5%. The method was successfully used in a pharmacokinetic study of adefovir dipivoxil in monkeys.CONCLUSION:The method is proved to be suitable for pre-clinical investigation of adefovir dipivoxil pharmacokinetics, which offers advantages of specificity and simple sample preparation compared with the previously reported methods.
What problem does this paper attempt to address?