Removal of Chromium Ions in an Expand Ion-Exchange Bed

赵会义,朱慎林,骆广生,汪家鼎
DOI: https://doi.org/10.3321/j.issn:1000-0054.2003.10.004
2003-01-01
Abstract:Wastewater containing chromium is a major source of environmental pollution. This paper analyzes the removal of hexavalent chromium from wastewater using an ionexchange bed with the strongly basic ion exchange resin Mp500. Static adsorption was first studied to determine the initial concentration and pH of the feed stream. Then, the influence of the expansion ratio on the outflow curve was studied. Finally, the expand bed was compared with the traditional fixed bed in terms of the ionexchange adsorption. The results show that the ion exchange process is greatly influenced by the initial concentration and pH of the feed flow with the best feed conditions being a concentration of 100~200 mg·L-1 and pH 3~5. The expansion ratio increases linearly with flow velocity with a maximum expansion ratio of less than 0.3. All of the expand beds provide better adsorption than the fixedbed.
What problem does this paper attempt to address?